恒溫水(shui)浴鍋(guo)(thermostat water bath)內(nei)水(shui)(shui)(shui)(shui)平放置不銹(xiu)鋼管(guan)(guan)狀加(jia)熱(re)器(qi),水(shui)(shui)(shui)(shui)槽的內(nei)部放有(you)(you)帶孔的鋁制(zhi)(zhi)擱板(ban)。上(shang)蓋上(shang)配有(you)(you)不同(tong)口徑(jing)的組合套圈,可適應不同(tong)口徑(jing)的燒瓶。水(shui)(shui)(shui)(shui)浴鍋左側有(you)(you)放水(shui)(shui)(shui)(shui)管(guan)(guan),恒(heng)溫(wen)(wen)水(shui)(shui)(shui)(shui)浴鍋右側是電(dian)氣(qi)箱(xiang),電(dian)氣(qi)箱(xiang)前面板(ban)上(shang)裝有(you)(you)溫(wen)(wen)度(du)(du)控(kong)制(zhi)(zhi)儀表、電(dian)源開關。電(dian)氣(qi)箱(xiang)內(nei)有(you)(you)電(dian)熱(re)管(guan)(guan)和傳(chuan)感器(qi)。該溫(wen)(wen)度(du)(du)控(kong)制(zhi)(zhi)系統采用(yong)了優(you)質電(dian)子(zi)元(yuan)件,控(kong)溫(wen)(wen)靈(ling)敏、性能(neng)可靠、使用(yong)方(fang)便。其工作原理:Cu50傳(chuan)感器(qi)將水(shui)(shui)(shui)(shui)槽內(nei)水(shui)(shui)(shui)(shui)的溫(wen)(wen)度(du)(du)轉換為電(dian)阻(zu)值,經過集(ji)成放大器(qi)的放大、比較后,輸出控(kong)制(zhi)(zhi)信號(hao),有(you)(you)效地控(kong)制(zhi)(zhi)電(dian)加(jia)熱(re)管(guan)(guan)的平均加(jia)熱(re)功率(lv),使水(shui)(shui)(shui)(shui)槽內(nei)的水(shui)(shui)(shui)(shui)保持恒(heng)溫(wen)(wen)。當(dang)被(bei)加(jia)熱(re)的物體要(yao)(yao)求受熱(re)均勻(yun),溫(wen)(wen)度(du)(du)不超(chao)過100℃時(shi),可以用(yong)水(shui)(shui)(shui)(shui)浴加(jia)熱(re)。水(shui)(shui)(shui)(shui)浴鍋通常用(yong)銅或鋁制(zhi)(zhi)作,有(you)(you)多個重(zhong)疊的圓圈,適于放置不同(tong)規格的器(qi)皿。注意不要(yao)(yao)把(ba)水(shui)(shui)(shui)(shui)浴鍋燒干,也不要(yao)(yao)把(ba)水(shui)(shui)(shui)(shui)浴鍋作沙盤(pan)使用(yong)。
恒溫(wen)水浴鍋的操作(zuo)說明
1、 設定(ding)溫度:
按(an)SET鍵可(ke)設定(ding)或查看溫(wen)度設定(ding)點。按(an)一下SET鍵數碼(ma)管字符開(kai)始(shi)閃動,表(biao)示儀(yi)表(biao)進入(ru)設定(ding)狀態,按(an)△鍵設定(ding)值增(zeng)加,按(an)▽鍵設定(ding)值減小,長按(an)△鍵或▽鍵數據會快速變動,再一次按(an)SET鍵儀(yi)表(biao)回(hui)到(dao)正常(chang)工作狀態溫(wen)度設定(ding)完畢。
2、 回差(cha)控制(XMT201-C)
按SET鍵3秒儀表進入內(nei)層(ceng)參數(shu)設(she)定狀態。第一個出現并閃動的參數(shu)為C00即(ji)回(hui)差值(zhi)(zhi),回(hui)差值(zhi)(zhi)控(kong)制(zhi)參數(shu)要慎重調整(zheng),儀表控(kong)制(zhi)加熱(re)(re)輸出值(zhi)(zhi)到(dao)設(she)定值(zhi)(zhi),當溫度下跌(die)到(dao)設(she)定值(zhi)(zhi)減(jian)回(hui)差值(zhi)(zhi)時又開始加熱(re)(re),在(zai)回(hui)差范圍內(nei)輸出(繼電(dian)器)是(shi)不動作的,這樣(yang)可(ke)減(jian)少繼電(dian)器動作次數(shu)以利延長繼電(dian)器壽(shou)命(ming)。回(hui)差值(zhi)(zhi)越(yue)(yue)大繼電(dian)器動作次數(shu)越(yue)(yue)少,回(hui)差值(zhi)(zhi)過大會降低控(kong)制(zhi)精度。調整(zheng)好回(hui)差參數(shu)后(hou)按SET鍵3秒鐘儀表回(hui)到(dao)正常工作狀態。
3、 提(ti)前量(liang)設置(XMT201-E)
按(an)SET鍵3秒(miao)儀(yi)表進(jin)入內(nei)層參數設定狀態。第一(yi)個(ge)出現(xian)并閃動(dong)的(de)參數為(wei)E00即加熱(re)(re)停止(zhi)的(de)提(ti)前(qian)(qian)量(liang)(liang),提(ti)前(qian)(qian)量(liang)(liang)參數要(yao)慎重調整,為(wei)減(jian)少溫度過沖,儀(yi)表控(kong)制加熱(re)(re)輸(shu)出時會提(ti)前(qian)(qian)截止(zhi)加熱(re)(re)。當溫度下跌(die)到提(ti)前(qian)(qian)量(liang)(liang)以下時又開始加熱(re)(re),在設定值(zhi)與提(ti)前(qian)(qian)量(liang)(liang)范圍(wei)內(nei)輸(shu)出(繼電(dian)器)是(shi)不動(dong)作的(de),這樣(yang)可(ke)減(jian)少繼電(dian)器動(dong)作次數以利延長繼電(dian)器壽命。提(ti)前(qian)(qian)量(liang)(liang)越大繼電(dian)器動(dong)作次數越少,提(ti)前(qian)(qian)量(liang)(liang)過大會降低控(kong)制精度。調整好提(ti)前(qian)(qian)量(liang)(liang)參數后按(an)SET鍵3秒(miao)鐘儀(yi)表回到正常工作狀態。
(1) 時間比例(li)設置(zhi)(XMT201-P)
按SET鍵3秒儀表進入內層參數(shu)設定狀態。
E:為比(bi)例帶偏移(yi)量,E參數(shu)可使(shi)實(shi)際控制點平衡(heng)移(yi)。即(ji)使(shi)時(shi)間比(bi)例的中心平移(yi),依加熱(re)系統的不同(tong)E值可正也(ye)可為負(fu)。
P:為比(bi)(bi)(bi)例(li)帶(dai),即(ji)(ji)比(bi)(bi)(bi)例(li)控制(zhi)值(zhi),為了便于(yu)理解同時也為了使比(bi)(bi)(bi)例(li)帶(dai)有更大(da)的表(biao)示空間,本儀表(biao)的比(bi)(bi)(bi)例(li)帶(dai)是(shi)單(dan)邊比(bi)(bi)(bi)例(li)帶(dai),即(ji)(ji)實際比(bi)(bi)(bi)例(li)帶(dai)是(shi)2倍P值(zhi)。以實際控制(zhi)點為中心從(cong)下至上在P值(zhi)范圍內輸出加熱(re)比(bi)(bi)(bi)例(li)按(an)0%-100%均布。
T:為(wei)加熱輸出循環(huan)周期,即繼電器工作(zuo)循環(huan)周期,T值小(xiao)控制效果好,但T值太小(xiao)繼電器會因頻繁工作(zuo)而減少壽命。一般T值取(qu)20-60秒(miao)。
(2) 智能控制參數設置(zhi)(XMT201-E)
按SET鍵3秒儀(yi)表進入內層參數設(she)定狀態。
E:這(zhe)個參數在P=0時是加熱停(ting)止的提前量,當P不(bu)等于(yu)0時儀表為智(zhi)能PID工作方式,P不(bu)等于(yu)0時E參數無(wu)意義。
P:為(wei)比例帶,即比例控制值(zhi),儀表(biao)以設定(ding)值(zhi)為(wei)中心P值(zhi)分布在設定(ding)點兩邊,在P值(zhi)范圍(wei)內儀表(biao)以PID方式工作。
T:為加熱輸出循環周(zhou)期(qi),即繼(ji)電(dian)器(qi)工作循環周(zhou)期(qi),T值小(xiao)控制效果好,但T值太小(xiao)繼(ji)電(dian)器(qi)會(hui)因頻繁(fan)工作而減少壽(shou)命。一般(ban)T值取20-60秒。
為(wei)簡化操作,儀表的積(ji)分時(shi)間(I)和微(wei)分時(shi)間(D)設計為(wei)隱藏參數,其(qi)默認值:I=180,D=45
(3) 誤差的修正(zheng):
在確(que)(que)認儀表(biao)(biao)顯(xian)示(shi)的(de)值(zhi)不(bu)是正確(que)(que)的(de)測量值(zhi)時可對顯(xian)示(shi)值(zhi)進行修(xiu)(xiu)正。按SET鍵3秒進入儀表(biao)(biao)內層菜單,第(di)一(yi)個(ge)出(chu)(chu)現并閃(shan)支的(de)參(can)數(shu)為(wei)(wei)E00即提前量,再按一(yi)次SET鍵出(chu)(chu)現并閃(shan)動的(de)參(can)數(shu)即誤差修(xiu)(xiu)正參(can)數(shu),配(pei)合△鍵或▽鍵可修(xiu)(xiu)改此參(can)數(shu)。誤差的(de)修(xiu)(xiu)正的(de)范圍(wei)為(wei)(wei)-9.9℃到+9.9℃,修(xiu)(xiu)正完成(cheng)后再按一(yi)下SET鍵退出(chu)(chu)。儀表(biao)(biao)出(chu)(chu)廠時修(xiu)(xiu)正值(zhi)為(wei)(wei)0.0,使用時要防(fang)止把(ba)顯(xian)示(shi)正確(que)(que)的(de)儀表(biao)(biao)修(xiu)(xiu)正至不(bu)正確(que)(que)。